Vue de la page 6
RC-13TC - Defining the RC-13TC Video Transport Controller 5
Figure 2: RC-13TC Video Transport Controller Rear Panel
# Feature Function
4 KNET TERM Termination Switch Use to set the K-NET bus termination (see
Section
5.2.2)
5 KNET 4-pin Removable Terminal
Blocks (1 and 2)
Connect to a master room controller or to another
auxiliary device.
Connect GND to GND, B to B, A to A, +12V to
+12V (see Section
5.2)
6 RESET (DEFAULT) Factory
Default Reset Button
Press and hold during power-up to erase all
custom programming.
Note: The current LCD text and all button actions
are erased
7 Ring Tongue Terminal Grounding
Screw
Connect to grounding wire (see Section 6)
8 RS-232 3-pin Removable
Terminal Block
For controlling a display, switcher, AV source or
other AV equipment
9 IR Infrared 2-pin Removable
Terminal Blocks (1 and 2)
Connect to IR emitters (see Figure 3).
Connect OUT 1 or OUT 2 to IR+ (anode), GND to
GND (cathode)
10 PROGRAM (USB) Connector Connect to a computer to program the unit ID,
LCD text and button actions using K-Config
Configuration software
11 Power Supply 2-pin Removable
Terminal Block
Connect to power supply (see Section 5.1.2).
Connect GND to GND, +12V to +12V
12 FW UPGRADE Switch For the use of Kramer service personnel only