Using Your TP-300FW FireWire Range Extender
7
connector on the second TP-300FW unit
1
.
3. Be sure that the power on each FireWire device is turned ON.
On each TP-300FW unit, the ACTIVE green LED lights indicating that a cable
from an external powered and fully functioning FireWire device is connected.
4. On each TP-300FW unit, connect the 12V DC power adapter to the power
socket and connect the adapter to the mains electricity.
The red ON LED lights.
5.2 Connecting Three TP-300FW Units to Extend the Distance to 200m
You can daisy-chain three TP-300FW units to extend the FireWire range to 200m.
To connect three TP-300FW units (using straight pin-to-pin STP cables) to extend
the FireWire distance to 200m, as illustrated in the example in Figure 3:
1
Alternatively, connect the CAT 5 CROSSED RJ-45 connector on the first TP-300FW unit to the CAT 5 CROSSED RJ-45 connector
on the second TP-300FW unit