Kramer-electronics VP-790 Manuel d'utilisateur Page 39

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 126
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 38
VP-790 Protocol API Functions 35
2.25 33BDetail Enhancement
2.25.1 207BbyOsdDetailSet
API index: 133
Sets the level of the detail enhancement algorithm.
Input Parameters
Name Type Range Description
Value UWORD32 0x00000000: off
0xFFFFFFFF: max
Detail enhancement value
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.25.2 208BbyOsdDetailGet
API index: 135
Retrieves the level of the detail enhancement algorithm from either cache or the
SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0x00000000: off
0xFFFFFFFF: max
Detail enhancement value
2.25.3 209BbyOsdDetailSave
API index: 134
Saves the level of the detail enhancement algorithm from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise