VP-790 Protocol API Functions 77
2.69 77BNetmask
2.69.1 334BbySetSubnetMask
API index: 113
Sets the netmask and saves the setting in the SPD immediately.
Input Parameters
Name Type Range Description
Value STRING nnn.nnn.nnn.nnn
String with 15 ASCII
characters /0 terminated
Netmask
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.69.2 335BbyGetSubnetMask
API index: 114
Retrieves the IP address from the SPD.
Input Parameters
Name Type Range Description
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value STRING nnn.nnn.nnn.nnn
String with 15 ASCII
characters /0 terminated
Netmask
2.70 78BOSD Enabling/Disabling
2.70.1 336BbyOsdEnableSet
API index: 3373
Switches off the OSD.
Note; This command only applies to HQView/LEDView with front panel LCD.
Input Parameters
Name Type Range Description
Value UWORD32 0: off
1: on
Switches the OSD on/off.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise