74 VP-790 Protocol - API Functions
2.66 Multiple Unit Vertical Set
2.66.1 byOsdMultipleUnitVerticalSet
API index: 3109
Sets the vertical address of the unit.
Input Parameters
Name Type Range Description
Value UWORD32 0x00-0x03 Vertical address of the unit. The
actual range is 0x00 to Vertical Width
1.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.66.2 byOsdMultipleUnitVerticalGet
API index: 3110
Retrieves the vertical address of the unit.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0x00-0x03 Vertical address of unit.
2.66.3 byOsdMultipleUnitVerticalSave
API index: 3111
Saves the number from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise