40 VP-790 Protocol - API Functions
2.30 DVI Output Range
2.30.1 byOsdDviOutRangeSet
API index: 3253
Sets DVI Output Range.
Input Parameters
Name Type Range Description
Value UWORD32 0: Default
1: Limited
2: Full
Sets DVI Output Range.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.30.2 byOsdDviOutRangeGet
API index: 3254
Retrieves the DVI Output Range setting from cache or from the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: Default
1: Limited
2: Full
DVI Output Range setting.
2.30.3 byOsdDviOutRangeSave
API index: 3255
Saves the DVI Output Range setting from cache into the SPD.