VP-790 Protocol API Functions 83
2.76 84BOutput Gamma
2.76.1 353BbyOsdGammaOutSet
API index: 346
Sets the Ouput Gamma.
Input Parameters
Name Type Range Description
Value UWORD32 0 .. 30 Ouput Gamma Value * 10
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.76.2 354BbyOsdGammaOutGet
API index: 348
Retrieves the Output Gamma Value from either cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0 .. 30 (fractional) Output Gamma Value * 10
2.76.3 355BbyOsdGammaOutSave
API index: 347
Saves the Output Gamma Value setting from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise